Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
1.
PLoS One ; 16(3): e0247635, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33770093

RESUMO

BACKGROUND: COVID-19 is characterized by a rapid change in the patient's condition, with major changes occurring over a few days. We aimed to develop and evaluate an emergency system for monitoring patients with COVID-19, which may be useful in hospitals where more severe patients stay in their homes. METHODOLOGY/PRINCIPAL FINDINGS: The system consists of the home-based patient unit, which is set up around the patient and the hospital unit, which enables the medical staff to telemonitor the patient's condition and help to send medical recommendations. The home unit allows the data transmission from the patient to the hospital, which is performed using a cell phone application. The hospital unit includes a virtual instrument developed in LabVIEW® environment that can provide a real-time monitoring of the oxygen saturation (SpO2), beats per minute (BPM), body temperature (BT), and peak expiratory flow (PEF). Abnormal events may be fast and automatically identified. After the design details are described, the system is validated by a 30-day home monitoring study in 12 controls and 12 patients with COVID-19 presenting asymptomatic to mild disease. Patients presented reduced SpO2 (p<0.0001) and increased BPM values (p<0.0001). Three patients (25%) presented PEF values between 50 and 80% of the predicted. Three of the 12 monitored patients presented events of desaturation (SpO2<92%). The experimental results were in close agreement with the involved pathophysiology, providing clear evidence that the proposed system can be a useful tool for the remote monitoring of patients with COVID-19. CONCLUSIONS: An emergency system for home monitoring of patients with COVID-19 was developed in the current study. The proposed system allowed us to quickly respond to early abnormalities in these patients. This system may contribute to conserving hospital resources for those most in need while simultaneously enabling early recognition of patients under acute deterioration, requiring urgent assessment.


Assuntos
COVID-19/patologia , Serviços de Assistência Domiciliar , Monitorização Fisiológica/métodos , Adulto , Doenças Assintomáticas/enfermagem , Temperatura Corporal , COVID-19/virologia , Estudos de Casos e Controles , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Aplicativos Móveis , Oximetria , Pico do Fluxo Expiratório/fisiologia , SARS-CoV-2/isolamento & purificação
2.
PLoS One ; 14(3): e0213257, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30845242

RESUMO

BACKGROUND: A better understanding of sickle cell anemia (SCA) and improvements in drug therapy and health policy have contributed to the emergence of a large population of adults living with this disease. The mechanisms by which SCA produces adverse effects on the respiratory system of these patients are largely unknown. Fractional-order (FrOr) models have a high potential to improve pulmonary clinical science and could be useful for diagnostic purposes, offering accurate models with an improved ability to mimic nature. Part 2 of this two-part study examines the changes in respiratory mechanics in patients with SCA using the new perspective of the FrOr models. These results are compared with those obtained in traditional forced oscillation (FOT) parameters, investigated in Part 1 of the present study, complementing this first analysis. METHODOLOGY/PRINCIPAL FINDINGS: The data consisted of three categories of subjects: controls (n = 23), patients with a normal spirometric exam (n = 21) and those presenting restriction (n = 24). The diagnostic accuracy was evaluated by investigating the area under the receiver operating characteristic curve (AUC). Initially, it was observed that biomechanical changes in SCA included increased values of fractional inertance, as well as damping and hysteresivity (p<0.001). The correlation analysis showed that FrOr parameters are associated with functional exercise capacity (R = -0.57), pulmonary diffusion (R = -0.71), respiratory muscle performance (R = 0.50), pulmonary flows (R = -0.62) and airway obstruction (R = 0.60). Fractional-order modeling showed high diagnostic accuracy in the detection of early respiratory abnormalities (AUC = 0.93), outperforming spirometry (p<0.03) and standard FOT analysis (p<0.01) used in Part 1 of this study. A combination of machine learning methods with fractional-order modeling further improved diagnostic accuracy (AUC = 0.97). CONCLUSIONS: FrOr modeling improved our knowledge about the biomechanical abnormalities in adults with SCA. Changes in FrOr parameters are associated with functional exercise capacity decline, abnormal pulmonary mechanics and diffusion. FrOr modeling outperformed spirometric and traditional forced oscillation analyses, showing a high diagnostic accuracy in the diagnosis of early respiratory abnormalities that was further improved by an automatic clinical decision support system. This finding suggested the potential utility of this combination to help identify early respiratory changes in patients with SCA.


Assuntos
Resistência das Vias Respiratórias , Anemia Falciforme/complicações , Sistemas de Apoio a Decisões Clínicas , Diagnóstico Precoce , Modelos Teóricos , Transtornos Respiratórios/diagnóstico , Mecânica Respiratória , Adulto , Feminino , Humanos , Masculino , Curva ROC , Transtornos Respiratórios/etiologia , Transtornos Respiratórios/patologia , Testes de Função Respiratória
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...